Now let s refer to nec 2017 section 210 8 for the answer to the gfci portion of our question.
Gfci required in laundry room.
The requirement for afci protection in kitchens and laundry areas as well as for branch circuit extensions or.
For receptacles that are not readily accessible and for receptacles dedicated for a specific appliance that is not easily moved.
A laundry room needs at least one 20 amp circuit for receptacles serving laundry equipment.
Where gfci protectio n is required.
Otherwise you probably need a a new washing machine or you will be fixing you old one so it runs on a gfci.
Gfci stands for ground fault circuit interrupter.
The code mandate was later expanded to include any receptacles in a laundry room in the 2014 nec.
See the nec code requirements in the table below for more specific information.
This circuit can supply a clothes washer or a gas dryer.
Gfci receptacles monitor any electric current imbalance between the circuit s hot and neutral conductor and shuts of the circuit if an imbalance is present.
Although the code does not specifically state that a washing machine receptacle has to be gfci the washing machine must have water service and a drain so its location becomes defined as a laundry.
Because by definition where the washing machine is located becomes the laundry the two phases of this requirement meant that initially a washing.
The only wiggle room for the washing machine is if it drains into a standpipe drain and there is no sink.
Gfci receptacle outlets electrical question.
Occupancy controlled lighting will be required too.
Gfci receptacles are required in bathrooms garages crawl spaces basements laundry rooms and areas where a water source is present.
Receptacles within 6 feet of a laundry sink were first required to be gfci protected by the 2005 edition of the national electrical code nec.
The nec doesn t require gfci protection for clothes washing machines specifically but it does for laundry areas.
It s a device that protects people from receiving shocks from faults in an electrical system.
The requirement for gfci protection in laundry areas was deleted.
If the laundry room does not have a window then an exhaust fan will be required along with a switch.
An electric dryer needs its own 30 amp 240 volt circuit wired with four conductors older circuits often have three conductors.
Yes as of the 2017 edition of the national electrical code nec any receptacles in a laundry room must be gfci protected.
Gfci protection is required for 125 volt to 250 volt receptacles supplied by single phase branch circuits rated 150 volts or less to the ground.
If the water supply is permanently connected to washing machines in a laundry area does it require a class a gfci protected receptacle.
All receptacles must be gfci protected.