The exhaust system typically uses metal venting often routed into a chimney stack to exhaust the combustion gases created in the furnace fire chamber.
Gas furnace venting into chimney.
The vent pipe must be firmly attached and sealed where it enters the chimney in order to prevent it from falling out to prevent air leaks into the chimney reducing the effective draft and to prevent flue gas leaks out of the chimney.
For gas venting appliances the chimney flue venting rules are more complex simply because of the variety of products on the market.
A gas stove can be vented through an existing chimney whether it is a manufactured or masonry chimney.
However using an interior chimney is extremely limited.
When venting two appliances separately into a common chimney always install the smaller flue pipe appliance with lowest gph input at a higher point into the chimney than the larger flue pipe for the appliance with the largest gph input.
This structure generally uses the furnace vent pipe through roofbecause the b venting pipe is designed in vertical manner.
This undermines the entire purpose of venting the furnace in the first place.
Also known as the type b this vent is operating on the natural air convection.
For many homes a gas furnace is the preferred heating device it has proven to be an efficient and reliable way of meeting household heating needs over the years.
To aid in removing the vent pipe a thimble or slip joint may be used.
For instance a 100 000 btu furnace venting into an interior chimney with a 38 square inch liner would not be allowed regardless of chimney height.
If any gaps remain and the vent isn t airtight the toxic gases will leak back into your home.
Refer to figure 2.
The vent pipe or flue is a vital component of the furnace that transmits emissions from the combustion process out of the building.
The height of the chimney the area of the liner and the input of the appliance all play a role in the use of the chimney.
The area around the flue piping should be sealed where it enters the chimney.
Taking care of the vent on your gas furnace is extremely important but working improperly and damaging your vent can have catastrophic results.
This chimney rule can be applied to wood burning fireplaces heating stoves and any oil fueled appliances but remember that manufacturer requirements have to be incorporated into it.
Furnaces that vent into chimneys can be hazardous but they don t have to be.
To ensure proper venting however a liner must first be installed in the chimney.
When the vent is withdrawing air from the house it expels the gas outside through the vent.